Today, CISA’s NCCIC-ICS published a control system security advisory for products from Nice and a medical device control system security advisory for products from Santesoft. They also updated a security advisory for products from Integration Objects. CISA also added a surveillance product vulnerability to their Known Exploited Vulnerabilities (KEV) catalog for products from Sunhillo.
Nice Advisory
This advisory describes 12 vulnerabilities in the Nice Linear eMerge E3-Series access control products. The vulnerabilities were reported by Gjoko Krstic from Zero Science Lab. Nice has a new version that mitigates the vulnerabilities. There is no indication that Krstic has been provided an opportunity to verify the efficacy of the fix.
The twelve reported vulnerabilities are:
Path traversal (2) - CVE-2019-7253 and CVE-2019-7254 (exploit),
Cross-site scripting - CVE-2019-7255 (exploit),
OS command injection - CVE-2019-7256 (exploit),
Unrestricted upload of a file with a dangerous type - CVE-2019-7257 (exploit),
Incorrect authorization - CVE-2019-7258 (exploit),
Exposure of sensitive information to unauthorized actor - CVE-2019-7259 (exploit),
Insufficiently protected credentials - CVE-2019-7260,
Use-of-hard coded credentials (2) - CVE-2019-7261 and CVE-2019-7265,
Cross-site request forgery - CVE-2019-7262 (exploit), and
Out-of-bounds write - CVE-2019-7264
NCCIC-ICS reports that a relatively low-skilled attacker could use publicly available code to remotely exploit the vulnerabilities to allow a remote attacker to gain full system access.
NOTE: On NIST.NVD.gov the listings for the above CVE’s show a 2019 report from Applied Risk with Krstic as the researcher. Exploits date back to November 2019.
Santesoft Advisory
This advisory describes an out-of-bounds read vulnerability in the Santesoft Sante FFT Imaging product. The vulnerability was reported by Michael Heinzl. Santesoft has a new version that mitigates the vulnerability. There is no indication that Heinzl has been provided an opportunity to verify the efficacy of the fix.
NCCIC-ICS reports that a relatively low-skilled attacker with uncharacterized access could exploit the vulnerability to allow a local attacker to execute arbitrary code once a user opens a malicious DCM file on affected FFT Imaging installations.
Integration Update
This update provides additional information on the OPC UA Server Toolkit advisory that was originally published on January 16th, 2024. The new information includes adding mitigation information.
New KEV Lising
CISA added CVE-2021-36380 Sunhillo SureLine OS command injection vulnerability to the KEV catalog. The vulnerability was originally reported (with proof-of-concept code) by Liam Glanfield of NCC Group.